预 绞 丝 UDC 621.315.6
GB 2337—85
Preformed armour rods 代替 GB 2337—80
国家标准局1985-01-23发布 1985-12-01实施
1 适用范围
本标准适用于架空电力线路在悬垂线夹中增加导线刚度和导线断股补修的预绞丝。
2 型式尺寸
2.1 预绞丝分为FYB型、FYH型。
2.2 预绞丝主要尺寸应符合下图及表1~2的规定:
表1 mm
型 号 |
适用导线 |
d |
d1 |
l |
每组根数 |
型 号 |
外 径 |
FYB-95/15
FYB-95/20
FYB-95/55 |
LGJ-95/15
LGJ-95/20
LGJ-95/55 |
13.61
13.87
16.00 |
3.6 |
11.4
11.4
13.3 |
420 |
13
13
16 |
FYB-120/7
FYB-120/20
FYB-120/25 |
LGJ-120/7
LGJ-120/20
LGJ-120/25 |
14.50
15.07
15.74 |
3.6 |
12.0
12.5
13.0 |
450 |
14 |
FYB-150/8
FYB-150/20
FYB-150/25
FYB-150/35 |
LGJ-150/8
LGJ-150/20
LGJ-150/25
LGJ-150/35 |
16.00
16.67
17.10
17.50 |
3.6 |
13.3
14.7
14.2
14.5 |
480 |
16 |
表2 mm
型 号 |
适用导线 |
d |
d1 |
l |
每组根数 |
型 号 |
外 径 |
FYH-95/15
FYH-95/20
FYH-95/55 |
LGJ-95/15
LGJ-95/20
LGJ-95/55 |
13.61
13.87
16.00 |
3.6 |
11.4
11.4
13.3 |
1400
1400
1500 |
13
13
16 |
FYH-120/7
FYH-120/20
FYH-120/25
FYH-120/70 |
LGJ-120/7
LGJ-120/20
LGJ-120/25
LGJ-120/70 |
14.50
15.07
15.74
18.00 |
3.6 |
12.0
12.5
13.0
14.9 |
1400
1400
1400
1800 |
14 |
4.6 |
FYH-150/8
FYH-150/20
FYH-150/25
FYH-150/35 |
LGJ-150/8
LGJ-150/20
LGJ-150/25
LGJ-150/35 |
16.00
16.67
17.10
17.50 |
3.6 |
13.3
14.7
14.2
14.5 |
1500 |
16 |
FYH-185/10
FYH-185/25
FYH-185/30
FYH-185/45 |
LGJ-185/10
LGJ-185/25
LGJ-185/30
LGJ-185/45 |
18.00
18.90
18.88
19.60 |
4.6 |
14.9
15.7
15.7
16.3 |
1800 |
14 |
FYH-210/10
FYH-210/25
FYH-210/35
FYH-210/50 |
LGJ-210/10
LGJ-210/25
LGJ-210/35
LGJ-210/50 |
19.00
19.98
20.38
20.86 |
4.6 |
15.9
16.6
16.9
17.3 |
1800 |
14 |
FYH-240/30
FYH-240/40
FYH-240/55 |
LGJ-240/30
LGJ-240/40
LGJ-240/55 |
21.60
21.66
22.40 |
4.6 |
17.9
17.9
18.6 |
1900 |
16 |
FYH-300/15
FYH-300/20
FYH-300/25
FYH-300/40
FYH-300/50
FYH-300/70 |
LGJ-300/15
LGJ-300/20
LGJ-300/25
LGJ-300/40
LGJ-300/50
LGJ-300/70 |
23.01
23.43
23.76
23.94
24.26
25.20 |
6.3 |
19.1
19.4
19.7
19.9
20.1
20.9 |
2000 |
13 |
FYH-400/20
FYH-400/25
FYH-400/35
FYH-400/50
FYH-400/65
FYH-400/95 |
LGJ-400/20
LGJ-400/25
LGJ-400/35
LGJ-400/50
LGJ-400/65
LGJ-400/95 |
26.91
26.64
26.82
27.63
28.00
29.14 |
6.3 |
22.3
22.1
22.3
23.0
23.2
24.8 |
2200 |
14 |
FYH-500/35
FYH-500/45
FYH-500/65 |
LGJ-500/35
LGJ-500/45
LGJ-500/65 |
30.00
30.00
30.96 |
6.3 |
24.9
24.9
25.7 |
2500 |
16 |
FYH-630/45
FYH-630/55
FYH-630/80 |
LGJ-630/45
LGJ-630/55
LGJ-630/80 |
33.60
34.32
34.82 |
7.8 |
27.9
28.5
28.9 |
2500 |
15 |
FYH-800/55
FYH-800/70
FYH-800/100 |
LGJ-800/55
LGJ-800/70
LGJ-800/100 |
38.40
38.58
38.98 |
7.8 |
31.8
32.1
32.3 |
2500 |
17 |
表中型号中字母及数字意义为:
F——防护;Y——预绞丝;H——护线条;B——补修条;数字——适用导线截面;分子表示铝截面;分母表示钢截面。
3 技术要求
3.1 预绞丝一般技术条件应符合GB2314—85《电力金具通用技术条件》的规定。
3.2 预绞丝按GB3196-82《铆氏用铝合金线材》,采用LF-10铝合金丝,其抗拉强度不低于264.7N/mm2 (264.7MPa)。
3.3 预绞丝端部应为光滑的半球形。
3.4 预绞丝表面应无裂纹、毛刺和严重划伤。
4 验收规则及试验方法
预绞丝的验收及试验按GB2317—85《电力金具验收规则、试验方法、标志与包装》进行。
5 标志与包装
预绞丝的标志与包装除按GB2317—85规定进行外,每组预绞丝应备有型号、厂标的标签,在包装物外应标志“勿压”字样。
--------------------------------------------------------------------------------------------------------
附加说明:
本标准由中华人民共和国水利电力部提出。
本标准由水利电力部南京电力金具设计研究所起草。
本标准主要起草人董吉谔、周铭泽、易健行、骆忆祖、余天衢、薄通。
|